External Wall Insulation (EWI) onto Masonry Clad

This build-up fixes wood fibre insulation to the outside of a masonry wall and finishes it with ventilated timber cladding instead of render. It suits solid-wall retrofits where a cladding finish is wanted, and where the wall needs to stay vapour open. Rigid wood fibre board is bonded to the wall and held by screws through the counter battening.

The build up

External Wall Insulation (EWI) onto Masonry Clad

1 2 3 4 5 6 7 INSIDE OUTSIDE
  1. 1

    Existing masonry wall

  2. 2

    Levelling Coat - Secil Reabilita Cal RB

    If required

  3. 3

    Bonding Coat - Secil Isovit Lime

    3mm onto back of board using 10mm notched trowel

  4. 4

    Rigid Wood Fibre Board - Steico Special Dry or Pavatex Isolair Multi

    Anchored with screws through the counter battening

  5. 5

    Counter battening

  6. 6

    Battening

  7. 7

    Feather edge board cladding, or similar

Schematic section, not to scale. Confirm thicknesses and fixings against manufacturer data before specifying.

Cross section diagram

Application notes
• Apply the bonding coat at 3mm to the back of the board with a 10mm notched trowel.
• Anchor the board with screws through the counter battening.
• Steico Special Dry is available from 60 to 200mm and Pavatex Isolair Multi from 30 to 200mm.
Choose the thickness from a project-specific U-value and condensation assessment.
• Batten sizes, cladding and fixings are the specifier's choice and are not bio space products.

Send us your drawings and we will quote the full system.