This build-up fills a timber stud frame built in front of a masonry wall with soft insulation, then lines it with a variable vapour control layer and wood wool board under lime plaster. It suits retrofits where the wall is uneven or the depth of insulation needs to be greater than a bonded board allows. A service void keeps wiring away from the vapour control layer.

The build up

Stud Wall Internal Wall Insulation (IWI) onto Masonry

3 2 1 7 6 5 4 INSIDE OUTSIDE
  1. 1

    Existing masonry wall

  2. 2

    Levelling Coat - Secil Reabilita Cal RB

    If required

  3. 3

    Soft Insulation - Steico Flex, Pavatex Pavaflex, Inditherm or Sisalwool

    Fully fill timber frame

  4. 4

    Variable Vapour Control Layer - Steico Multi Renova or Sopravap Hygro

  5. 5

    Service void

  6. 6

    Wood Wool Board - Savolit Plus or Fibrolith

    Fixed using Wood Wool Screws and Wood Wool Washers

  7. 7

    Lime Plaster Finish

    Secil Isovit Lime 3mm, mesh, another 3mm Secil Isovit Lime, then 2mm (2 × 1mm passes) Secil Reabilita Cal AC Fino

Schematic section, not to scale. Confirm thicknesses and fixings against manufacturer data before specifying.

Cross section diagram

Application notes
• Fully fill the timber frame with the soft insulation.
• Fix the wood wool board with Wood Wool Screws and Wood Wool Washers.
• Savolit Plus is CE marked to EN 13168 and is Euroclass B-s1,d0, with a μ value of 5. It comes in
15mm for internal use on walls.
• Plaster system: 3mm Isovit Lime, mesh, a second 3mm Isovit Lime coat, then 2mm of Reabilita
Cal AC Fino in two 1mm passes.